Safety Footwear EN ISO 20345: S1P, S3 and S5 Compared
How this guide was written: every figure below is either taken from a published standard named in the sentence, or read from the specification of an item in our own catalogue. Where a number is an industry rule of thumb rather than a standard, the text says so. No customer names, certificate numbers or inspection results are quoted unless they come from an order file.
Safety footwear is the most frequently purchased PPE item on any site and the one most often bought on price and appearance. The consequences of buying wrong are not usually dramatic; they are the slow kind — a sole that debonds after eight months in storage, a penetration plate that does not cover the ball of the foot, a pair that fits in the shop and is unbearable after four hours.
EN ISO 20345 is the standard that defines what the markings mean. Understanding four of its requirements — toe cap energy, penetration resistance, slip rating and sole material — is enough to write a specification that holds up.
What the Toe Cap Test Actually Guarantees
Safety footwear under EN ISO 20345 is defined by its toe cap, which must withstand an impact of 200 joules and a compression of 15 kilonewtons, with a defined minimum clearance remaining inside the cap after the test.
Two things follow from that definition, and both are frequently misunderstood.
First, 200 J is a laboratory energy, not a statement about falling objects on your site. It corresponds roughly to a 20 kg mass dropped from one metre. A concrete block falling from scaffold height delivers more, and no toe cap is rated for it.
Second, the standard tests the cap and the clearance beneath it, not the whole shoe. A cap that passes can still transmit force through a deformed upper, and the shoe can fail at the sole or the upper long before the cap is reached.
Footwear marked SB has the toe cap only. Everything above SB adds features, and those features are what the S-codes describe. The overall PPE and safety supplies range shows how footwear sits alongside head, hand and eye protection in a site issue list.
Decoding the S-Codes
The S-codes are cumulative. Each level includes the requirements of the one before it.
| Code | Adds | Typical use |
|---|---|---|
| SB | 200 J toe cap, basic requirements | Light duty, dry indoor |
| S1 | Closed seat region, antistatic, heel energy absorption, fuel oil resistance | Warehouse, light assembly |
| S2 | S1 plus water penetration and water absorption resistance of upper | Wet indoor, food handling |
| S3 | S2 plus penetration resistance and cleated outsole | General construction, site work |
| S4 | All-polymeric or all-rubber footwear, antistatic, heel energy absorption | Wet processing, cleaning |
| S5 | S4 plus penetration resistance and cleated outsole | Heavy wet and muddy sites |
The practical purchasing decision for construction is usually between S1P and S3. The “P” suffix denotes penetration resistance added to S1 or S2, so S1P is S1 with a penetration-resistant insert — common in lighter site shoes. S3 adds water resistance of the upper and a cleated outsole on top of that.
A common error is to buy S3 for a dry indoor workshop because it is “the best”. S3 footwear is heavier, less breathable and more expensive, and on a dry floor the cleated outsole gives no benefit. The correct specification is the lowest code that covers the actual hazards, plus any project-specific additions. The footwear category lists the codes as they are actually stocked, which is often narrower than the full standard.
Penetration Resistance: 1100 N and Its Limits
The penetration test drives a nail through the sole at a defined force — 1100 newtons under the 2011 edition — and requires that it does not penetrate.
Three limitations are worth knowing.
The insert does not cover the whole sole. It covers a defined area, and the toe and heel regions are typically outside it. A nail entering at the extreme edge of the sole is not covered by the test.
Steel inserts protect against force but conduct cold and can trigger metal detectors. Non-metallic inserts avoid both problems but are generally thicker and, in some designs, cover a smaller area. The choice is a trade-off, not an upgrade.
The test is a static force test. It does not replicate a nail that is driven by a vehicle wheel or a nail that penetrates at an angle through the side of the sole. Penetration-resistant footwear reduces risk; it does not eliminate it.
Slip Resistance and the 2022 Revision
Slip resistance under the 2011 edition is marked as SRA (ceramic tile with sodium lauryl sulphate solution), SRB (steel floor with glycerol) or SRC (both tests passed). SRC is not a higher performance level than SRA or SRB; it simply means both surfaces were tested.
The 2022 revision of EN ISO 20345 changed the marking scheme for slip and penetration resistance. In practice, buyers now see both generations in the market: legacy S1P, S3 and S5 markings on product made to the 2011 edition, and the newer marking scheme on product certified to the 2022 edition.
The procurement rule is not to prefer one edition, but to require consistency: the edition stated on the EU type-examination certificate must match the marking on the product and on the packaging. Mixed or missing edition references are the most common documentation defect in imported footwear.
Slip testing is also a floor-specific result. A boot that scores well on ceramic tile with detergent may perform poorly on oily steel plate, and vice versa. Where the floor is known — a food plant, a workshop with cutting fluid — specify the test surface that matches the floor, not the highest available rating.
Sole Materials: PU, Rubber and Hydrolysis
Sole material determines comfort, weight and shelf life, and it is where the least visible failures occur.
Polyurethane (PU) is light, cushions well and resists abrasion. Two-layer PU soles are common in mid-price footwear. The weakness is hydrolysis: PU absorbs moisture and, in warm humid storage, the sole can begin to crumble before the boot is ever worn. A pair bought in bulk and stored for two years in a non-air-conditioned warehouse may fail at the first use.
Rubber is heavier and less cushioned but resists hydrolysis, heat and many chemicals. For tropical or humid climates, and for footwear that will sit in storage, rubber is the safer specification.
TPU and injected soles sit between the two, with good abrasion resistance and better hydrolysis behaviour than PU.
The practical controls are a manufacturing date on the product, a first-in-first-out stock policy, and a storage condition that avoids heat and humidity. A boot with no date marking cannot be rotated and should be treated as a documentation non-conformity.
Heat, Cold and Welding Spatter
Three additional markings matter in specific trades.
HRO indicates outsole resistance to contact heat at 300 °C for one minute — relevant for paving and asphalt work, not for welding.
HI is heat insulation of the sole complex, for hot floors. CI is cold insulation, for refrigerated environments.
Welding spatter is a different hazard, covered by welding-specific footwear requirements rather than by the general S-codes. A standard S3 boot with a synthetic upper will burn through; specify welding footwear for welders rather than adding an HRO boot and assuming equivalence.
ESD and Antistatic Are Not the Same
Antistatic footwear (marking A) is specified as a resistance range from 0.1 to 1000 megohms. It dissipates static slowly enough to avoid a spark and fast enough to prevent a charge building.
ESD footwear is a narrower requirement, typically 0.1 to 100 megohms, tested to the EN 61340 series for electronics manufacturing.
The two are not interchangeable, and neither protects against electric shock. Antistatic footwear must not be used as primary protection against live electrical work — that is a separate product category with its own standard. If a site asks for “electrical safety shoes”, clarify whether they mean antistatic, ESD or dielectric, because the three are different products.
Sizing, Fit and Why Buying by Size Fails
Footwear sizing is not standardised across manufacturers. A European 43 from one factory is not the same internal volume as a 43 from another, and toe cap shape changes the usable space even at the same length.
Two practical controls. First, fit to the longest foot and check toe clearance with the foot loaded — the cap must not contact the toes when the wearer is standing. Second, buy a sample pair per size for trial before a bulk order, and record which factory and last the sample came from. Bulk orders that skip the trial step produce returns that exceed the price saving.
What to Require From a Supplier
A specification that avoids arguments: standard and edition (EN ISO 20345:2011 or :2022), S-code, slip test surfaces, penetration insert type, sole material, size range, marking requirements (CE, size, manufacturer, standard, code, year and quarter of manufacture), EU type-examination certificate number, and declaration of conformity.
Footwear is Category II PPE under Regulation (EU) 2016/425, which requires an EU type-examination by a notified body and a declaration of conformity. The same document logic applies to safety helmets, and the PPE import documentation guide sets out the document set for customs. The glove cut-level guide covers the hand protection counterpart.
Honest List
Standard and publicly documented: EN ISO 20345 as the safety footwear standard, with the 2011 and 2022 editions both in force in the market; 200 J impact and 15 kN compression for the toe cap; the cumulative S1 to S5 definitions; 1100 N penetration resistance under the 2011 edition; antistatic range 0.1–1000 MΩ; HRO at 300 °C for one minute; classification as Category II PPE under Regulation (EU) 2016/425.
Experience-based judgement: the practical ranking of S1P versus S3 for construction; the hydrolysis risk profile of two-layer PU in humid storage; the statement that non-metallic inserts generally cover a smaller area; the fitting and trial-sample procedure.
Requires site confirmation: the exact edition the certificate cites and whether the marking matches; the specific floor surfaces for slip testing; the hazard set that determines the minimum S-code; the storage conditions and stock rotation practice; whether the client requires ESD rather than antistatic; local customs requirements for PPE.