Kress KD022 Spirit Level
Price on request
What a spirit level actually claims
The model is KD022, a spirit level, and its claim is narrow but absolute: that the vial reads level when the surface is level, within a stated tolerance. Everything else about the tool, the frame, the finish and the grips, exists to make that one claim reliable in the hands of somebody who is not being careful.
That is why a level is worth checking on arrival rather than trusting. A level that is out is worse than no level at all, because it produces work that is confidently wrong and has to be dismantled to be corrected.
Checking a level against itself
Put the level on a surface, read the bubble, then turn it end for end and read it again in the same place. If the bubble sits in the same position relative to the vial markings both ways, the level is reading true. If it moves, the error is in the level, not in the surface.
Repeat the test on a surface tilted slightly, so the bubble is off centre. The reversal test is most sensitive when the bubble is displaced, and a level that passes only at centre is a level that will mislead you on a slope.
Temperature and the vial
Vials are filled with a liquid whose viscosity changes with temperature, which changes how quickly the bubble settles but not, in a sound instrument, where it settles. What temperature does affect is the frame, and a frame that is heated on one side will bend.
Bring a level to the temperature of the work before trusting it. A level carried from a warm van into a cold morning reads differently for the first ten minutes, and that is exactly when the first course is being set.
Dropping it, and the failure nobody sees
A dropped level rarely breaks. It bends, or the vial shifts in its bed, and the change is small enough to escape notice and large enough to matter over a long run. Any level that has had a fall should be re-tested before it is used on work that counts.
Store it where it cannot fall rather than where it is convenient. A level kept on the floor of a van is a level that has been dropped many times and tested once.
Reading the bubble properly
Read with the level at eye level and both edges of the bubble visible against the lines. Reading from above or below introduces parallax, and parallax is a systematic error that no amount of care with the tool will remove. Wait for the bubble to settle. A bubble that is still moving is a bubble that is telling you about your hand, not about the surface.
Handling on site
Wipe the base before use. A single piece of grit under the base holds one end off the surface, and the error that introduces is larger than most people believe. This is the most common cause of a level reading perfectly and a shelf being visibly out.
Do not use the level as a straight edge for marking or as a lever. Both habits are common and both take the tool out of tolerance in a way that is invisible until the work is finished.
An acceptance test in two minutes
Run the reversal test on a surface you know. Check the vial for a bubble that is the right size and does not stick to the glass. Check the base for flatness by rocking it on a known flat surface and looking for movement. Then check the second vial if the tool has one, since a level can be true in one plane and out in the other, and the plane that fails is always the one nobody tested.
| Model | KD022 |
|---|---|
| Type | Spirit Levels |

Reviews
There are no reviews yet.